Functional Test Results of a High Power Patch Array Antenna

Report No. ARL-TR-4352
Authors: Canh Ly
Date/Pages: January 2008; 30 pages
Abstract: Mechanical and electrical test results of a high power two-patch array antenna [ARL Invention pending ARL-07-18, Ly, et al.] are presented. The mechanical test was run for 55 minutes for each axis of the antenna. The electrical test was conducted using a high power RF source (>1 KW) with single and two-patch array antennas. Although the first mechanical test results indicated that the screws of the antenna cover are loosened about 1/4 turn, and right angle connectors inside the antenna enclosure box were loosened about a fraction of a turn, the antenna still sustained all functional operations. The antenna uses air dielectric to endure a high average power for the system that operates at S-Band in order to neutralize unattended microwave devices. This development is to fulfill part of the Army Technology Objective (ATO), Network Centric Warfare for the U.S. Army Communications-Electronics Research, Development, and Engineering Center (CERDEC), and Research and Development Engineering Command (RDECOM).
Distribution: Approved for public release
  Download Report ( 4.114 MBytes )
If you are visually impaired or need a physical copy of this report, please visit and contact DTIC.
 

Last Update / Reviewed: January 1, 2008